[docs]defcond2sal(C,T,p):"""Compute salinity from conductivity, according to :cite:t:`lewis_practical_1981`. Example ------- >>> cond2sal(C=52, T=25, p=1013) 34.20810771080768 """p=pressure2mbar(p)/100# convert hPa (mbar) -> dbarT=temperature2C(T)a0=0.008a1=-0.1692a2=25.3851a3=14.0941a4=-7.0261a5=2.7081b0=0.0005b1=-0.0056b2=-0.0066b3=-0.0375b4=0.0636b5=-0.0144c0=6.766097e-1c1=2.00564e-2c2=1.104259e-4c3=-6.9698e-7c4=1.0031e-9A1=2.070e-5A2=-6.370e-10A3=3.989e-15B1=3.426e-2B2=4.464e-4B3=4.215e-1B4=-3.107e-3R=C/42.914# units: mS/cm# TODO: check input units of Conductivity! "If you are working in conductivity units of Siemens/meter (S/m), multiply your conductivity values by 10 before using the PSS 1978 equations. "# TODO: maybe use units from log file for auto-conversion and print a hint or so (this could be already done during the read routine)rT=c0+c1*T+c2*T**2+c3*T**3+c4*T**4alpha=(A1*p+A2*p**2+A3*p**3)/(1+B1*T+B2*T**2+B3*R+B4*T*R)Rp=1+alphaRT=R/(rT*Rp)k=0.0162# TODO: check sign! +/-?ξ=np.sqrt(RT)ψ=b0+b1*ξ+b2*ξ**2+b3*ξ**3+b4*ξ**4+b5*ξ**5dSal=ψ*(T-15)/(1+k*(T-15))salinity=a0+a1*ξ+a2*ξ**2+a3*ξ**3+a4*ξ**4+a5*ξ**5+dSalreturnfloat(salinity)
[docs]defwater_vapor_pressure(T,S):"""Compute the water vapor pressure by means of the temperature [K] and the salinity [PSU] following :cite:t:`weiss_nitrous_1980`. Parameters ---------- S: float or pandas.Series Salinity in PSU T: float or pandas.Series Temperature (°C gets converted into Kelvin) """T=temperature2K(T)pH2O=np.exp(24.4543-67.4509*(100/T)-4.8489*np.log(T/100)-0.000544*S)returnpH2O
[docs]defppm2uatm(xCO2,p_equ,input='wet',T=None,S=None):"""Convert mole fraction concentration (in ppm) into partial pressure (in µatm) following :cite:t:`dickson_guide_2007` .. math:: pCO_2 = xCO_2 \\cdot p_\\text{equ} Parameters ---------- xCO2: float or pandas.Series The measured CO2 concentration (in ppm) p_equ: float or pandas.Series The measured pressure (in hPa, Pa or atm) at the equilibrator (hint: you might want to smoothen your time series) input: str [default: "wet"] Either "wet" or "dry", specifying the type of air, in which the concentration is measured. If the CO2 concentration is measured in dry air, one must correct for the water vapor pressure. In this case, make sure to also provide T (temperature in Kelvin) and S (salinity in PSU) as arguments. T: float or pandas.Series [default: None] Temperature in Kelvin (needs to be provided if xCO2 is measured in dry air) S: float or pandas.Series [default: None] Salinity in PSU (needs to be provided if xCO2 is measured in dry air) """# Pa or hPa -> atmp_equ=pressure2atm(p_equ)ifinput=="dry":pH2O=water_vapor_pressure(T,S)elifinput=="wet":pH2O=0else:raiseIOError("Input must be either 'dry' or 'wet'.")pCO2_wet_equ=xCO2*(p_equ-pH2O)returnpCO2_wet_equ